
BWP Flush Doors from the house of Architwood are made from selected pinewood frames and evenly sized batons. Our high-density block board doors provide excellent insulation against dust, heat and sound. Made from quality, imported timber, they possess high resistivity to borers and termites.
| S.No. | Test | IS : 2202 Requirements | Sitcoply Results |
|---|---|---|---|
| 1. | Moisture Content (%) | 10 - 12 | 11 |
| 2. | Flatness of Shutter "(twist, cupping and warping)" |
not more than 1 mm | 0.5mm |
| 3. | Local Planess (surface smoothness) |
not more than 0.5 mm | 0.3mm |
| 4. | Impact Indentation | not more than 0.2 mm by a weight of 0.5 kg | Pass |
| 5. | Flexure Resistance (residual deflection) | not more than 2 mm | 1.1mm |
| 6. | Edge Loading a) Residual deflection b) Lateral buckling |
not more than 0.2 mm not more than 1.5 mm |
0.15mm 0.08mm |
| 7. | Shock Resistance | no visible damage after 25 blows of 5 kg | Pass |
| 8. | Buckling Resistance a) Initial deflection b) Residual deflection |
not more than 40 mm not more than 5 mm |
25mm 2mm |
| 9. | Slamming of the Shutter | no visible impact after 25 impacts of 15 kg | Pass |
| 10. | Misuse of the Shutter | no permanent deformation after the test | Pass |
| 11. | End Immersion | no delamination after immersion | 2.8% |
| 12. | Adhesion of Plies | excellent | Excellent |
| 13. | Glue Adhesion | no delamination of the glue line | Pass |
| 14. | Screw Holding Strength (kg) | > 200 | 350 |
| 15. | Preservative Treatment | Two Tier Treatment: 1. Lumber and Veneers are treated with preservatives 2. Glue Line is fortified with non- leachable organophosphorous compound (USA technology) |
Pass Pass |
| 16. | Specific Gravity | 0.60 | 0.60 |
| 17. | Water Absorption | < 2% | 1% |
| 18. | Nail Holding Strength (kg) | > 100 | 250 |